- 70%

Conventional Fire Alarm Control System Smoke Detector 2 Wire DC 9-36V Optical Smoke alarm Universal

Original price was: ₱1,000.00.Current price is: ₱299.00.

Added to wishlistRemoved from wishlist 0

It adopts the principle of infrared light refraction by the particles in smoke to detect the fire circuit.
Mainly consists of infrared transmitter and receiver, the transmitter and receiver are placed in an optical labyrinth.
The transmitter tube and receiver tube are placed in the optical labyrinth optical labyrinth can be shielded from outside interference with stray light, but does not affect the entry of smoke.
interference, but does not affect the entry of smoke. In the smoke state, only receive a very weak
Infrared light, smoke, due to the scattering effect, so that the receiving optical signal increase
interference and reduce power consumption, the transmitter circuit adopts pulse mode, which can improve the
life of the transmitter tube.
– Operating voltage: AC/DC 9-24V
– Standby current: ?16mA
– Alarm current: ?19mA
– Operating temperature: -10.C~+50.C
– Ambient temperature: Maximum 95%RH (no condensation)
– RF interference resistance: 10MHz – 1GHz 20V/m
– Alarm output: normally open / normally closed optional, contact capacity DC24V100mA
Reset mode: automatic reset / power failure reset optional
– Coverage area: When the height of space is 6m-12m, a detector
Coverage area: When the height of space is 6m-12m, the protection area of one detector is 80 square meters for general protection site; when the height of space is below 6m, the protection area is 60 square meters.
When the space height is below 6m, the protection area is 60 square meters. Specific parameters should be
Specific parameters should be based on the automatic fire alarm system design code GB50116-98.
– Sensitivity: 0.5db/m (±0.1db/m)
This product is a non-coding smoke detector, with a pair of switching
output contacts, according to the actual need to choose normally open or normally closed output. Normal
When working normally, the indicator light flashes every 8 seconds; when in alarm, the indicator light is always on and the alarm output contact is activated.
When alarm occurs, the indicator light is always on, and the alarm output contact operates at the same time.
This product is a non-coding smoke detector, with a pair of switching
output contacts, according to the actual need to choose normally open or normally closed output. Normal
When working normally, the indicator light flashes every 8 seconds; when in alarm, the indicator light is always on and the alarm output contact is activated.
When alarm occurs, the indicator light is always on, and the alarm output contact operates at the same time.

User Reviews

0.0 out of 5
0
0
0
0
0
Write a review

There are no reviews yet.

Be the first to review “Conventional Fire Alarm Control System Smoke Detector 2 Wire DC 9-36V Optical Smoke alarm Universal”

Your email address will not be published. Required fields are marked *

Conventional Fire Alarm Control System Smoke Detector 2 Wire DC 9-36V Optical Smoke alarm Universal
Conventional Fire Alarm Control System Smoke Detector 2 Wire DC 9-36V Optical Smoke alarm Universal

Original price was: ₱1,000.00.Current price is: ₱299.00.

Shopping cart